User manual for DoorKing’s convenience open system for vehicle gate operators, covering installation, operation modes, and battery requirements.
This manual provides instructions for installing and operating the convenience open system for DoorKing vehicle gate operators, including models 1600, 6000, and 9000. The system allows manual or automatic gate opening during power outages using batteries. It is not designed for continuous operation during outages. The manual details setup options, terminal connections, and battery maintenance.
The system supports manual mode for residential use and automatic mode for apartment complexes. It includes DIP-switch settings for operation mode, direction, and power-up behavior. Battery replacement is recommended every two years. The system requires testing monthly to ensure functionality. This manual is written in Chinese.
| Battery Type | 12-volt, 3.0 amp-hour gel-cell batteries |
|---|---|
| Battery Replacement Interval | every two years on average |
| Operation During Power Outage | one-time open only |
No, it is designed as a convenience enhancement only and cannot provide continuous gate operation during a power outage.
It uses two 12-volt, 3.0 amp-hour gel-cell batteries, which should be replaced every two years on average.
It offers manual mode for residential use and automatic mode for apartment complexes and gated communities.