1601/1602 Barrier Gate Operator Installation Guide for use with models 1601-080/081 1602-080/081 with circuit board 1601-010 Rev. V or higher Supplemental Manual available (P/N 2340-065) for 1601-081, 1601-088 and 1602-081 for optional battery backup system with additional wiring information.
The DoorKing 1601 and 1602 are vehicular operator-class II, III, or IV systems designed for single-lane traffic control. The unit features a G90 galvanized steel housing with a worm gear mechanism running in an oil bath, operating on 115/230/460 VAC power.
| Class | II, III, IV |
|---|---|
| Horsepower | 1/2 or 1 HP |
| Housing Material | G90 galvanized steel, painted white |
| Mechanism | worm gear running in a continuous oil bath |
| Temperature Range | 10ºF to 140ºF (-12ºC to 62ºC) |
| Voltage | 115/230/460 VAC |
The 1601 operator has been designed for high usage single lane (14 feet maximum) vehicular traffic control.
A suggested minimum of 3/4-inch conduit should be used to avoid damage to wire insulation during pulls.
The concrete base should allow for curing for 48 hours to ensure it is even and leveled.
The unit complies with UL 325 and UL 991 safety standards and is ETL Listed.