The CODE Skyrocket Tc-182 is an 18-channel digital switch silicon box that works with lighting controllers outputting DMX-512/1990 signals. It provides 18 output channels, each rated for a maximum load of 2 kW, and can be powered from three-phase or single-phase AC at 220 V, 50–60 Hz.

The manual explains the front-panel DIP switch, indicators, channel fuses and power switch, along with the rear-panel DMX input/output, fuse holder, 18 lighting load terminals and three-phase four-wire power input. It also covers single-phase and three-phase wiring, load connections, DMX-512 signal connections, DMX start address setting with DIP switches 1–9, and output memory mode selection with switch 10. This manual is written in Chinese.

What's inside

  • Technical specifications
  • Panel controls
  • Rear panel connections
  • Unpacking check
  • Main power connection
  • Lighting load circuit connection
  • DMX-512 control signal connection
  • DMX-512 address setting
  • Output memory control mode setting

Specifications

Control channels18 channels
Maximum load per output channel2 kW
Control signal inputDMX-512/1990 standard digital control signal
Power supplyThree-phase or single-phase AC, 220 V, 50–60 Hz
No-load power consumption27 W
Dimensions483 mm (W) x 88 mm (H) x 305 mm (D)
Weight5.5 kg
Output circuit fuse rating10 A

Frequently asked questions

How many control channels does the CODE Skyrocket Tc-182 have?

It has 18 control channels.

What is the maximum load for each output channel?

Each output channel can handle a maximum load of 2 kW.

How do you calculate the DMX start address from the DIP switches?

Add the values of DIP switches 1 through 9 and add 1; the result is the DMX start address.

What does DIP switch position 10 control?

It sets the output memory mode: in the A position the outputs hold their last values when the DMX signal is interrupted, while in the B position output memory is off.