CAREL humiSteam Basic (UEY*) humidifier user manual covering installation, water and steam connections, parameters, alarms, maintenance and wiring diagrams.
The CAREL humiSteam Basic (UEY*) is an isothermal immersed-electrode humidifier that produces and distributes steam; the manual covers models UE001 to UE065 in single-phase and three-phase versions. The model code identifies the rated steam production, the control type (Y = UEY basic), the power supply and options such as a cylinder for low conductivity or a UL certified version for the American market.
The user manual describes opening the packaging, positioning, wall-mounting and fitting the front cover, then the supply water, drain water and drain tempering connections. It also covers steam distribution with jet distributors, linear distributors for air ducts, steam blowers and hoses, electrical connections, the alarm and auxiliary contacts and the RS485 supervisory network, before the display and keypad, configuration parameters, alarms, maintenance and spare parts, wiring diagrams and general features and technical specifications.
| Steam temperature | 100 °C / 212 °F |
|---|---|
| Warranty on materials | 2 years from the date of production, excluding consumables |
| Control type in model code | Y = UEY basic |
| Cylinder option in model code | 1 = cylinder for low conductivity |
The humidifier delivers steam at 100 °C / 212 °F and contains high temperature components, so there is a danger of burns.
Only qualified personnel who are aware of the necessary precautions and able to perform the required operations correctly may install, operate or carry out technical service on the product.
The mains power supply must be disconnected before accessing inside parts or during maintenance and installation, because the humidifier contains live electrical components.
The warranty on materials is 2 years from the date of production, excluding consumables.