Calex 41000 Series Power Module Operators Guide

User manual for Calex 41000 Series power modules, covering installation, connection, protection, and parallel use.


Calex 41000 Series Power Module Operators Guide - cover page
Brand
Calex
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
155 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
55910A02C63E2A0EE4D4DB78C95CEBB8

About this manual

This guide explains how to install and operate Calex 41000 Series power modules, including AC connection, fusing, overload protection, and parallel operation. The modules are designed for professional installers and must be mounted in enclosures with safety protection and adequate airflow. Cooling is achieved via convection or fan cooling for improved reliability.

Technical specifications include input voltage options (115V or 230V AC), output voltage tolerance, load regulation, isolation, and environmental ratings. Each model has specific output voltage and current ratings with corresponding input fuse requirements.

What's inside

  • AC Connection and Fusing
  • Disconnect Devices
  • Overload Protection
  • Parallel Connection
  • Technical Specification
  • Input Connection Diagrams

Specifications

Input Voltage115 or 230 V AC (±10%) link selectable, 50 to 60 Hz
Output Voltage Tolerance±5% maximum
Load Regulation±0.2% for 50% load change
Line Regulation±0.05% for 10% line change
Isolation: Input to Output3750 V AC minimum
Temperature RatingStandard range: 0°C to +50°C full-rated, derated linearly to 40% at 70°C
Safety StandardIn accordance with EN60950
Overall Dimensions119.2 x 45 x 73.2 mm
Weight0.37 kg (41245; 0.53 kg)
MaterialPolycarbonate (self extinguishing to UL 94V-0)
Environmental RatingIP20

Frequently asked questions

What is the input voltage range for the 41000 Series?

The input voltage is 115 V AC or 230 V AC (±10%) and is link selectable.

How should the power supply be cooled?

The power supply is convection cooled and requires free air to flow around the unit. Additional cooling can be achieved by mounting on a large metal surface or using fan cooling.

What is the overload protection feature?

All models are fitted with foldback current limiting, factory set at 120% of I max to minimize erroneous tripping due to line spikes.

Can multiple units be connected in parallel?

Yes, units of the same type can be connected in parallel to achieve greater output currents, with the unit having the highest output voltage supplying the load current first.

Download PDF (155 KB)