User manual for Calex 41000 Series power modules, covering installation, connection, protection, and parallel use.
This guide explains how to install and operate Calex 41000 Series power modules, including AC connection, fusing, overload protection, and parallel operation. The modules are designed for professional installers and must be mounted in enclosures with safety protection and adequate airflow. Cooling is achieved via convection or fan cooling for improved reliability.
Technical specifications include input voltage options (115V or 230V AC), output voltage tolerance, load regulation, isolation, and environmental ratings. Each model has specific output voltage and current ratings with corresponding input fuse requirements.
| Input Voltage | 115 or 230 V AC (±10%) link selectable, 50 to 60 Hz |
|---|---|
| Output Voltage Tolerance | ±5% maximum |
| Load Regulation | ±0.2% for 50% load change |
| Line Regulation | ±0.05% for 10% line change |
| Isolation: Input to Output | 3750 V AC minimum |
| Temperature Rating | Standard range: 0°C to +50°C full-rated, derated linearly to 40% at 70°C |
| Safety Standard | In accordance with EN60950 |
| Overall Dimensions | 119.2 x 45 x 73.2 mm |
| Weight | 0.37 kg (41245; 0.53 kg) |
| Material | Polycarbonate (self extinguishing to UL 94V-0) |
| Environmental Rating | IP20 |
The input voltage is 115 V AC or 230 V AC (±10%) and is link selectable.
The power supply is convection cooled and requires free air to flow around the unit. Additional cooling can be achieved by mounting on a large metal surface or using fan cooling.
All models are fitted with foldback current limiting, factory set at 120% of I max to minimize erroneous tripping due to line spikes.
Yes, units of the same type can be connected in parallel to achieve greater output currents, with the unit having the highest output voltage supplying the load current first.