Installation guide for the Billi Alpine 125Tap (XL, XT, XR) covering components, location, water, power, drainage, dispenser and XR remote panel installation.
Billi Alpine 125Tap is an internally installed cold-water dispenser system with options XL, XT and XR. This installation guide covers the components, planned unit location, water supply, power, drainage, dispenser assembly and, for XR models, remote panel installation.
Installation must be performed by a licensed trades person. The guide specifies supply pressure and temperature limits, a 10 A power outlet, drain connection size and distance, cupboard and benchtop clearances, and flush or proud mounting of the XR remote panel.
| Water supply pressure | 200–500 kPa |
|---|---|
| Water supply temperature | 5°C–30°C |
| Power supply | Single 10 A standard power outlet |
| Flex cord length | 1 metre |
| Drain connection size | 40–50 mm |
| Drain connection distance | Within 1 m of unit |
| Stop tap distance | Within 450 mm of unit |
| Cupboard minimum width | 220 mm |
| Cupboard minimum depth | 365 mm |
| Dispenser mounting hole diameter | 32 mm |
| Maximum benchtop thickness | 50 mm |
| XR remote panel cutout | 121 mm high x 70 mm wide, 20 mm minimum depth |
| XR proud mount cable hole | 25 mm wide x 45 mm high |
It must be installed by a licensed trades person in accordance with AS/NZS 3500.1 and AS/NZ 3500.2.
No, it is designed for internal installation only.
The supply pressure must be 200–500 kPa.
A single 10 amp standard power outlet is required.