Berthold LB 115 Data Logger stationary dose rate monitoring system with 7-inch touch screen, flexible alarms, and up to two probes.
The Berthold LB 115 Data Logger is a stationary dose rate monitoring system with a head unit featuring a 7 inch colour touch screen display, user-friendly software, and electronics for flexible alarm signalling. It can be combined with up to two external probes and is designed for dose rate measurement in nuclear facilities, nuclide laboratories, hot cells, and other laboratories and production facilities.
The leaflet describes flexible alarm concepts with up to four alarm thresholds per channel, five double relays, remote control, flexible data transfer, password-protected input parameters, and mechanical, electrical, ambient, power supply, software, interface, and measuring-task specifications.
| Dimensions | 30 cm × 25 cm × 10 cm (W × H × D), stainless steel |
|---|---|
| Weight | approx. 5.5 kg incl. signal tower |
| Display | 7 inch colour touch screen, 800 × 480 pixels |
| Potential-free relay | 5 × 2 change-over contact, max. 50 VAC/120 VDC, 3 A |
| Optional 24 VDC supply | Internal, max. connection power 12 W / 500 mA |
| On/off switch | Key switch |
| Temperature range | -25 °C to 55 °C (-25 °C to 50 °C with signal tower) |
| Relative humidity | 0 – 93 % (at +35 °C), non-condensing |
| Protection class | IP65 |
| Pollution degree | 2 |
| Power supply voltage | 100 to 240 VAC, 50/60 Hz |
| Power | max. 60 W (at 20 °C) |
| Fuse | T1.6 A / 250 V (slow bow) |
| Measuring modes | Ratemeter, moving average and counter / timer operation |
| Data memory | Up to 100,000 measured values |
| Back-up function | Parameter Up-/Download for external data backup |
| Alarm modes | 4 alarm thresholds, 1 integral threshold and 1 failure threshold per probe |
| Service mode | Various service routines such as background measurement, system test and hardware test |
| Ethernet | 10 / 100 / 1000 Mb |
| USB Host | USB 2.0 (HS); max. 200 mA; Updates via USB |
| USB Device | USB 2.0 (HS) |
| RS485 | 9600 – 115200 Baud, 8 data bits, 1 start bit, 1 stop bit, no parity, no handshake, cable length up to 1200 m, max. 15 participants, cable STP |
| Probes | 2 × RS485 + 24 VDC for detector interface |
| Digital inputs | 3 × galvanically isolated, low active (High = 5 V at input) |
| Current outputs | 2 × galvanically isolated, load 300 Ω, modes: 0 – 20 mA, 0 – 24 mA, 4 – 20 mA |
| Detector-Interface dimensions | 9 cm × 11.5 cm × 5.5 cm (W × H × D) |
| Detector-Interface weight | approx. 0.5 kg |
Up to two external probes can be connected.
It has a 7 inch colour touch screen display with 800 × 480 pixels.
The protection class is IP65.
It can store up to 100,000 measured values.