BECO MEMBRAN PS Beer Filter Cartridge Restoration Manual

This manual provides step‑by‑step instructions for restoring BECO MEMBRAN PS Beer filter cartridges using cold, hot, and special cleaning procedures.


BECO MEMBRAN PS Beer Filter Cartridge Restoration Manual - cover page
Brand
Beco
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
354 KB
Published
06 October, 2026
Updated
06 October, 2026
MD5 checksum
7F7D71CD280B6F20BDF6E10ACDE9AAA8

About this manual

The restoration process begins with a regular cold‑water rinse of at least 2 minutes at the filter’s flow direction, followed by a hot‑water rinse at 80 °C for at least 5 minutes while maintaining a reverse pressure of 0.5 bar. After rinsing, the cartridge should be left in hot water overnight for optimal recovery.

If the pressure differential exceeds 0.5 bar and regular rinses are insufficient, a special cleaning sequence using alkaline (NaOH) and acidic solutions is required. The procedure includes controlled temperature, concentration, and pH steps, followed by thorough rinses until no residual chemicals remain. Safety notes advise using Eaton‑recommended water and contacting Eaton technical support for assistance. This manual is written in Chinese.

What's inside

  • Restoration Overview
  • Regular Cold Water Rinse
  • Hot Water Rinse
  • Special Cleaning Procedure
  • Acid and Alkali Cleaning Steps
  • Circulation Cleaning
  • Safety and Contact Information

Specifications

Maximum pressure differential for regular rinse< 0.5 bar
Reverse pressure during rinses0.5 bar (50 kPa)
Hot water rinse temperature80 °C
Alkaline cleaning solution concentration1‑2% NaOH, pH 13, 55 °C
Acid cleaning solution concentration0.5% phosphoric acid, pH 3.2, 55 °C
Circulation cleaning pressure≈ 100 kPa (1.0 bar)

Frequently asked questions

How long should the cold‑water rinse be performed?

The cold‑water rinse should be performed for at least 2 minutes in the direction of filtration.

What temperature is required for the hot‑water rinse?

The hot‑water rinse should be done with water at 80 °C.

When is special cleaning required for the filter cartridge?

Special cleaning is required when the pressure differential exceeds 0.5 bar and regular cold‑ and hot‑water rinses do not fully restore the cartridge.

What are the key steps for the alkaline cleaning stage?

First rinse with cold water, then warm water (50 °C), followed by a 1‑2% NaOH solution at pH 13 and 55 °C for 20 minutes, and finally rinse until no alkaline residue remains.

Download PDF (354 KB)