The B10 Instrument User Manual provides specifications, connection instructions, operation guide, error codes, and maintenance tips.
This manual describes the main technical parameters of the B10 instrument, including accuracy, measurement range, non‑linearity, power requirements, and internal resolution. It also details how to connect sensors, the serial communication interface, and the large‑screen display.
The guide explains each button’s function, how to configure communication settings, adjust measurement parameters, interpret error codes, and perform proper maintenance and safety precautions to ensure reliable operation. This manual is written in Chinese.
| Measurement Range | 0–3000 d |
|---|---|
| Nonlinearity | ≤0.01% FS |
| System Operating Voltage | DC 5 V |
| Division Values | 1/2/5/10/20/50 |
| AD Output Speed | 40 samples/s (selectable 10 or 40) |
| Internal Resolution | ≤240 000 |
| Battery | 6 V 4 Ah |
| Power Adapter Input | AC 120‑240 V |
| Power Adapter Output | DC 12 V / 500 mA |
Press the 【归零】 key briefly; the instrument will zero within its zero‑range.
ERR -3 indicates that the input data value is incorrect.
Short‑press the 【单位】 key to toggle the weighing unit.
Connect the supplied 12 V / 500 mA adapter to the instrument to charge the battery.