About this manual

The Autonics H-18TX4S Series is an LCD display PID temperature controller in a 48×48 mm panel-mount package. It uses a large LCD with 15.3 mm white PV characters and 11-segment PV and SV displays, and its compact design reduces depth by about 30% compared with similar-sized Autonics models.

The controller has a 50 ms sampling period and offers relay output, SSR drive output, and selectable current or SSR drive output. It supports ON/OFF, P, PI, PD and PID control, RTD Pt100/Cu50 and thermocouple inputs, alarm outputs, transfer output, and RS485 Modbus RTU communication. Parameters can be set and monitored with the DAQMaster device management program.

What's inside

  • Features
  • DAQMaster device management program
  • Ordering Information
  • Specifications
  • Connections
  • Dimensions and panel cut-out
  • Product Mounting
  • Unit Description
  • Parameter Group
  • SV setting

Specifications

Power supply100-240VAC 50/60Hz
Power consumptionMax. 8VA
Input typeRTD DPt100Ω, Cu50Ω; TC K(CA), J(IC), L(IC), T(CC), R(PR), S(PR)
Display method11 segments (PV: white, SV: green), other display (yellow) with LCD method
PV character size6.9×15.3mm
Relay output250VAC 3A 1a
SSR drive outputMax. 12VDC ± 2V 20mA
Control methodON/OFF control, P, PI, PD, PID control
Sampling period50ms
Communication outputRS485 Communication output (Modbus RTU method)
Protection structureIP50 (front panel, IEC standards)
WeightApprox. 135.2g (approx. 85.2g)

Frequently asked questions

What is the sampling period of the H-18TX4S Series temperature controller?

The sampling period is 50 ms.

Which temperature sensors can the controller accept?

It accepts RTD Pt100Ω and Cu50Ω sensors, as well as K, J, L, T, R and S thermocouples.

Can I choose between current output and SSR drive output?

Yes. Users can select between current output and SSR drive output through parameter settings of a single unit.

What communication method does the controller support?

It supports RS485 communication using the Modbus RTU method.