Operating instructions for the ARGO-HYTOS RPE3-062x/xS3 solenoid-operated hydraulic directional control valve with axial spool position sensor and SIL 3…
This document serves as the official operating instruction manual for the ARGO-HYTOS RPE3-062x/xS3 hydraulic directional control valve. It covers product description, technical parameters, installation guidelines, commissioning procedures, normal operation, maintenance tasks such as seal replacement and coil changing, and disposal instructions.
| Maximum operating pressure (P, A, B channels) | 350 bar |
|---|---|
| Maximum operating pressure (T channel) | 210 bar |
| Functional safety level | SIL 3, PL d |
| Connection pattern | DN 06 according to ISO 4401 |
| Mounting torque (M5x45 bolts) | 8,9 + 1 Nm |
| Max operating temperature (NBR seals) | -30 to +80 °C |
| Max operating temperature (FPM/Viton seals) | -20 to +80 °C |
The valve may be used for a maximum pressure of 350 bar in the P, A, B channels.
The valve has certified functional safety SIL 3 and PL d.
It is designed for a plate connection pattern DN 06 according to ISO 4401.
The four M5x45 bolts must be tightened to a torque of 8,9 + 1 Nm.