Installation, operation and maintenance instructions for Amiad Filtomat M100 series M104LPN and M106LP electronically controlled filters.
Amiad Filtomat M100 series models M104LPN and M106LP are electronically controlled filters. This manual covers their installation, operation and maintenance, including safety instructions, technical specifications, dimensional drawings, self-cleaning cycle, troubleshooting, parts schedules and drawings, and warranty information.
Technical specifications include a maximum flow rate of 180 m3/h, working pressure from 2.5 to 10 bar, total filtration area of 6150 cm2, and molded screen filtration degrees from 500 to 80 micron. The manual also describes commissioning, first operation, maintenance, winterization, screen and dirt collector removal and reinstallation, and control tube schemes.
| Maximum flow rate | 180 m3/h (790 USgpm) |
|---|---|
| Minimum working pressure | 2.5 bar (38 psi) |
| Maximum working pressure | 10 bar (150 psi) |
| Inlet/Outlet diameter | 100, 150 mm (4", 6") |
| Maximum working temperature | 60 C (140 F) |
| Empty/Full weight, M104LPN | 90 kg / 170 kg (198 lb / 375 lb) |
| Empty/Full weight, M106LP | 115 kg / 225 kg (243 lb / 496 lb) |
| Exhaust valve | 40 mm (1 1/2") |
| Flushing cycle time | 15 seconds |
| Wasted water per cycle | 125 liter (35 US gallon) at 2 bar (30 psi) |
| Minimum flow for flushing | 26 m3/h (115 USgpm) at 2 bar (30 psi) |
| Flush criteria | Differential pressure of 0.5 bar (7 psi), time and manual operation |
| Filtration degrees available | 500, 300, 200, 130, 100, 80 micron (0.5, 0.3, 0.2, 0.13, 0.1, 0.08 mm) |
| Construction materials | Filter housing polyester coated carbon steel 37-2; fine screen stainless steel 316 with molded plastic support structure |
The maximum flow rate is 180 m3/h (790 USgpm); consult the manufacturer for optimum flow depending on filtration degree and water quality.
Molded screen filtration degrees are available in 500, 300, 200, 130, 100 and 80 micron.
Each flushing cycle wastes 125 liter (35 US gallon) at 2 bar (30 psi).
The flushing cycle time is 15 seconds, depending on the working pressure.