Amiad 2-inch manual steel filter 910101-00057 installation and maintenance instructions covering safety, installation, cleaning, and parts.
This document provides installation and maintenance instructions for the Amiad 2-inch Manual Steel Filter, catalog number 910101-00057, dated January 2017. It includes safety instructions, principle of operation, installation site recommendations and instructions, cleaning steps, a typical installation drawing, and a parts schedule and drawing.
According to the text, water flows through a stainless steel filtration element from the inside out, and the filter has to be cleaned manually. Cleaning is required when the pressure drop between pressure checkpoints exceeds 0.7–1.0 bar (10–15 psi), or when downstream pressure or flow becomes unacceptably low. The manual also warns not to loosen the filter lid bolts until pressure has been released.
| Cleaning pressure drop threshold | 0.7–1.0 bar (10–15 psi) |
|---|---|
| Molded weavewire screen | S/ST316L, 500 sq.cm, 130 micron, Amiad 2" |
| Perforated screen | S/ST316L, 500 sq.cm, 1500 micron, Amiad 2" |
Clean it when the pressure drop between pressure checkpoints exceeds 0.7–1.0 bar (10–15 psi), or when downstream pressure or flow becomes unacceptably low.
Water flows through the filter element from the inside out, so dirt and debris accumulate on the inside surface.
Pressure must be released first; the manual warns not to loosen the filter lid bolts until pressure has been released.
Remove the filter element and clean it by spraying a hard stream of water on its outside surface; stubborn dirt may be removed with a light to medium stiffness brush.