AGA Six-Four Series DC6 Natural Gas and Propane Gas Range Owners Manual

AGA Six-Four Series DC6 gas range owners manual covering installation, technical data, operation, cooking guidance, cleaning, and servicing.


AGA Six-Four Series DC6 Natural Gas and Propane Gas Range Owners Manual - cover page
Brand
AGA
Category
Other
Document type
User Manual
Language
English
Pages
60
File format
PDF
File size
850 KB
Published
16 November, 2026
Updated
16 November, 2026
Model
DC6
MD5 checksum
5BDCE9B2AE16367733D56969479BE330

About this manual

This owners manual for the AGA Six-Four Series DC6 range covers natural gas and propane gas models for use in the USA and Canada. It includes installation requirements, technical data, gas and electrical connections, product dimensions, and location clearances.

The user's guide covers the control panel, gas hotplate, pan supports, simmering oven, broiler, ovens, minute timer, automatic cooking control, and cleaning. A servicing section covers parts removal and includes a wiring diagram.

What's inside

  • Technical Data
  • Installation
  • Fitting and Product Dimensions
  • Electrical Connection
  • Connecting to Gas
  • Location
  • Cooker Stability
  • Pressure Testing
  • Levelling and Mobility Wheels
  • User's Guide

Specifications

Weight of appliance220 kg
Top oven power rating2.2 kW
Broiler element power rating2.45 kW
Slow cooking oven power rating1.0 kW
Lower oven (fan) power rating2.2 kW
Electrical supply240 volt, 60 Hz, single phase, 30 amp
Natural gas pressure setting4" W.G.
Propane gas pressure setting10" W.G.
Burner ignitionH.T. spark
Side wall clearance above cookerNot less than 75mm (3") horizontally
Front service clearanceMinimum 1000mm
Gas connection1/2" NPT female threaded elbow
Supply piping minimum inside diameter3/8 I/D Flexiline

Frequently asked questions

What gas pressure settings apply to the AGA DC6 range?

The natural gas pressure setting is 4" W.G. at the rear right side of the hotplate, and the propane pressure setting is 10" W.G.

What electrical supply does the AGA DC6 range require?

It requires a four-wire single phase 240-volt, 60-Hz AC-only supply on a separate 30-ampere circuit, fused on both sides of the line.

Where is the wiring diagram located?

The wiring diagram is located on the back of the appliance, and the document also includes a wiring diagram in the servicing section.

What should be done if gas is smelled?

Do not try to light any appliance, touch an electrical switch, or use a phone in the building. Call the gas supplier from a neighbor's phone, and if the supplier cannot be reached, call the fire department.

Download PDF (850 KB)