AGA Six-Four Series DC6 Natural Gas and Propane Gas Range Owners Manual

AGA Six-Four Series DC6 Natural Gas and Propane Gas Range Owners Manual

User Manual 60 pages · 850 KB · EN

This owners manual for the AGA Six-Four Series DC6 range covers natural gas and propane gas models for use in the USA and Canada. It includes installation requirements, technical data, gas and electrical connections, product dimensions, and location clearances.

The user's guide covers the control panel, gas hotplate, pan supports, simmering oven, broiler, ovens, minute timer, automatic cooking control, and cleaning. A servicing section covers parts removal and includes a wiring diagram.

Read online

AGA DC6 specifications

Weight of appliance220 kg
Top oven power rating2.2 kW
Broiler element power rating2.45 kW
Slow cooking oven power rating1.0 kW
Lower oven (fan) power rating2.2 kW
Electrical supply240 volt, 60 Hz, single phase, 30 amp
Natural gas pressure setting4" W.G.
Propane gas pressure setting10" W.G.
Burner ignitionH.T. spark
Side wall clearance above cookerNot less than 75mm (3") horizontally
Front service clearanceMinimum 1000mm
Gas connection1/2" NPT female threaded elbow
Supply piping minimum inside diameter3/8 I/D Flexiline

Source: AGA Six-Four Series DC6 Natural Gas and Propane Gas Range Owners Manual

All AGA DC6 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What gas pressure settings apply to the AGA DC6 range?

The natural gas pressure setting is 4" W.G. at the rear right side of the hotplate, and the propane pressure setting is 10" W.G.

From: AGA Six-Four Series DC6 Natural Gas and Propane Gas Range Owners Manual

What electrical supply does the AGA DC6 range require?

It requires a four-wire single phase 240-volt, 60-Hz AC-only supply on a separate 30-ampere circuit, fused on both sides of the line.

From: AGA Six-Four Series DC6 Natural Gas and Propane Gas Range Owners Manual

Who should install this gas appliance?

All gas appliances must be installed by a competent person, specifically a qualified Gas Safe Registered Engineer.

From: AGA SIX-FOUR SERIES DC6 (FFD) Natural Gas Cooker Owner's Manual

What type of gas does this cooker use?

This appliance is designed for use with Natural Gas G20.

From: AGA SIX-FOUR SERIES DC6 (FFD) Natural Gas Cooker Owner's Manual