Installation and operating instructions for the AGA Hadley smoke exempt wood stove, covering flue and ventilation requirements, fuels, lighting and maintenance.
This document gives installation and operating instructions for the Hadley wood stove, described as a smoke exempt appliance. It opens with safety warnings about hot surfaces and supervision of children and infirm persons, then sets out general handling and installation notes, the Clean Air Act 1993 and smoke control area requirements, and pre-installation checks such as removing stickers and accessories before first use.
The installation part covers chimney and flue requirements, down draughts, ventilation and combustion air, commissioning and handover, location, floor protection and clearance to combustibles. The operating part covers air controls, recommended fuels, refuelling, de-ashing, maintenance and chimney cleaning, lighting, fire safety, CO alarms, fire brick and glass replacement, summer shutdown, and an exploded view with parts list.
| Chimney/flue diameter | 150 mm or equivalent cross-sectional area |
|---|---|
| Minimum chimney/flue height | 4.5 metres from the flue spigot to the top of the chimney/flue |
| Minimum continuous draught | 12 pascals |
| Soot fire temperature the flue must withstand | 1000 degrees |
| Air inlet spigot pipe diameter | 120 mm externally |
| Minimum combustion air duct diameter | 120 mm, non-combustible |
| Maximum combustion air duct length | 10 metres |
| Minimum rigid flue pipe above the appliance | 0.6 metres |
| Maximum horizontal flue run | 150 mm |
The chimney or flue must have a diameter of 150 mm or an equivalent cross-sectional area, and it must never be connected to a smaller flue.
The Hadley stove is recommended for use in smoke controlled areas when burning wood logs only and fitted with a factory modified air control.
The duct must be at least 120 mm in diameter, non-combustible, ducted to the outside, with no sharp bends and a maximum length of 10 metres.
No, the document states that this stove contains no asbestos, but care should be taken if asbestos may be disturbed during installation.