Advanced Science And Novel Technology Company PRBS20C PRBS Generator User Manual

User manual for the PRBS20C broadband PRBS generator for microwave communication testing and prototyping.


Advanced Science And Novel Technology Company PRBS20C PRBS Generator User Manual - cover page
Brand
Advanced Science And Novel Technology Company
Category
Signal Generators
Document type
User Manual
Language
English
Pages
6
File format
PDF
File size
617 KB
Published
31 October, 2026
Updated
31 October, 2026
MD5 checksum
1716FFB5485606181F9C3C1C7D3B311D

About this manual

This document provides operating instructions for the ASNT_PRBS20C, a broadband PRBS generator designed for microwave communication applications. It includes setup steps, control descriptions, and electrical specifications. The board features a programmable clock synthesizer up to 22GHz, external clock input, adjustable PRBS data amplitude and phase, and USB 2.0 software control.

Key controls include clock input selection, PRBS pattern selection (PRBS7/PRBS15), sync output configuration, amplitude and phase adjustment, and jitter insertion for testing purposes.

What's inside

  • Operation
  • Clock Input Control
  • PRBS Selection/Reset Control
  • Clock Output Control
  • Sync Controls (Trigger)
  • Amplitude Controls
  • Phase Shift Controls
  • PRBS Drift (Jitter Insertion) Controls
  • Electrical Characteristics
  • Board Dimensions

Specifications

Operating Frequency Range20 Mbps – 22.0 Gbps
Clock Output Frequency0.02 - 22 GHz
PRBS Output Amplitude50mV to 1.2V peak-to-peak
Phase AdjustmentUp to 155ps
Power SupplySingle positive 5V
USB InterfaceUSB 2.0
Sync Output Division Ratio1 to 256
Duty Cycle (Sync Output)50%
Rise/Fall Time15-19 ps
Operating Temperature-25°C to 85°C

Frequently asked questions

What is the maximum frequency supported by the PRBS20C?

The board supports frequencies up to 22GHz.

How is the PRBS data amplitude controlled?

The PRBS data amplitude is adjustable from 50mV to 1.2V peak-to-peak.

Can the board be controlled via software?

Yes, it features a USB 2.0 interface for software-based control via a GUI.

What is the purpose of the Sync Output?

The Sync Output provides a divided copy of the input clock, primarily used to trigger a high-speed oscilloscope.