ADLINK NuDAQ/NuIPC 9112 Series Multi-function DAS Cards User's Manual

User's manual for the ADLINK NuDAQ/NuIPC 9112 Series multi-function data acquisition cards for PCI and 3U CompactPCI, covering installation, programming…


ADLINK NuDAQ/NuIPC 9112 Series Multi-function DAS Cards User's Manual - cover page
Brand
ADLINK
Category
Other Electronics
Document type
User Manual
Language
English
Pages
79
File format
PDF
File size
401 KB
Published
06 November, 2026
Updated
06 November, 2026
MD5 checksum
1507D58E39F4E61474857D1E68AC60C4

About this manual

This manual provides comprehensive instructions for the ADLINK NuDAQ/NuIPC 9112 Series, which includes the PCI-9112 and cPCI-9112 multi-function data acquisition cards. The document covers features such as 12-bit analog input resolution, 16 digital I/O channels, and programmable counters, suitable for data logging and signal analysis applications.

What's inside

  • Introduction
  • Installation
  • Registers Format
  • Operation Theorem
  • C/C++ Library
  • Calibration
  • Software Utilities

Specifications

Resolution12-bit
Sampling RateUp to 110Khz
Analog Input Channels16 single-ended or 8 differential
Digital I/O Channels16 inputs and outputs
Converter TypeSuccessive approximation type
Operating Temperature0 ° C ~ 60 ° C

Frequently asked questions

What are the supported input ranges for the ADLINK 9112?

The supported ranges include Bipolar: ±10V, ± 5V, ±2.5V, ±1.25V, ±0.625V and Unipolar: 0~10V, 0~5V, 0~2.5V, 0~1.25V.

What trigger modes are available for the ADLINK 9112?

The available trigger modes are Software, Timer Pacer, and External trigger.

What is the data transfer capability of the PCI-9112?

The PCI-9112 supports Bus mastering DMA, Program control, and Interrupt data transfer modes.