ABB ProcessMaster FEP300 electromagnetic flowmeter technical specification covering models, accuracy, materials, connections, outputs, approvals and…
ProcessMaster FEP300 is an electromagnetic flowmeter for process industry applications. The document describes the compact ProcessMaster 300 version with basic functionality, including intuitive operation, non-contact programming keys, Easy Set-up, NAMUR status messages, help texts on the display, and diagnostic functions such as ScanMaster.
It lists compact models, nominal diameters from DN 3 to 2000, process flange connections, lining and electrode materials, IP65 or IP67 protection, fluid temperatures from -25 to 180 °C, power supply options, current, pulse and switch outputs, HART as standard communication with optional PROFIBUS PA or FOUNDATION Fieldbus, and Ex and pressure equipment approvals. This manual is written in Italian.
| Measurement accuracy | Standard 0.4% of measured value; optional 0.2% of measured value |
|---|---|
| Nominal diameter | DN 3 to 2000 (1/10 in to 80 in) |
| Process connection | Flange according to DIN 2501 / EN 1092-1, ASME B16.5 / B16.47, JIS, AS2129 |
| Nominal pressure | PN 10 to 100; ASME CL 150, 300, 600, 900, 1500, 2500 |
| Lining materials | Hard rubber (DN 15 to 2000), soft rubber (DN 50 to 2000), PTFE (DN 10 to 600), PFA (DN 3 to 200), ETFE (DN 25 to 600), Linatex (DN 50 to 600) |
| Conductivity | Greater than 5 µS/cm (20 µS/cm for demineralized water) |
| Electrode materials | Stainless steel, Hastelloy B, Hastelloy C, platinum-iridium, tantalum, titanium, tungsten carbide |
| Process connection material | Steel or stainless steel |
| Protection rating | IP65 or IP67 |
| Fluid temperature | -25 to 180 °C (-13 to 356 °F) |
| Power supply | 100 to 230 V AC (-15/+10%), 24 V AC (-30/+10%), 24 V DC (-30/+30%) |
| Current output | 4 to 20 mA, active or passive |
| Pulse output | Active or passive, adjustable on site via software |
| Switch output/input | Optocoupler with programmable function |
| Display | Graphic display, adjustable |
| Housing | Compact form, single-chamber or dual-chamber |
| Communication | HART standard; PROFIBUS PA and FOUNDATION Fieldbus optional |
| Ex approvals | ATEX/IECEx Zone 1, 2, 21, 22; FM/cFM Class 1 Div. 1 (up to DN 300) or Div. 2; NEPSI Zone 1, 2; GOST Zone 1, 2 |
| Pressure equipment directive | 97/23/EC, conformity assessment category III, fluid group 1 |
| CRN | On request |
The standard accuracy is 0.4% of the measured value, with 0.2% available as an option.
HART is standard; PROFIBUS PA and FOUNDATION Fieldbus are available as options.
The housing is specified with IP65 or IP67 protection.
The measured fluid can range from -25 to 180 °C (-13 to 356 °F).