This document introduces the product features, usage instructions, model specifications, etc. of the Okiflex cable system.
This manual describes the Koganei PC Wiring System, including its branch units, terminal blocks, and various input/output configurations. It explains how the system converts 32‑I/O arrangements from different PLC manufacturers to a common 16‑I/O pin layout, enabling easy connection to Koganei manifold solenoid valves and other equipment.
The document also lists handling precautions, power supply requirements, cable options, crimping tools, check units, and order codes for accessories such as Okiflex cables and custom cable assemblies. Detailed connection and application examples illustrate wiring for control panels, sensors, and solenoid valves.
| Power supply voltage | DC 24 V |
|---|---|
| Maximum control solenoids per unit | 16 |
| Maximum current per unit | 2.0 A (1.0 A for 8‑input/output unit) |
| Cable length options | 0.5 m to 20 m |
| Available lead counts for Okiflex cable | 20 leads and 40 leads |
| Standard I/O configuration | 32 inputs / 32 outputs |
Each unit can handle up to 2.0 A, but the 8‑input/output unit is limited to 1.0 A.
Okiflex cables are offered in lengths from 0.5 m up to 20 m.
A standard branch unit converts 32 inputs or outputs to a common 16‑input/16‑output arrangement.
The system uses a 24 V DC power supply.