WSF-100 series ultrasonic flowmeter is a new design based on the foreign similar products, a general time-difference type ultrasonic flowmeter instrument, the product is widely used in industrial environment for continuous measurement of clean and uniform liquid flow and heat.
This manual covers the WSF-100 series ultrasonic flow meter and heat meter, describing its purpose, key features, and safety precautions. It explains the time‑difference measurement principle and the device's suitability for continuous measurement of clean, uniform liquids in industrial settings.
The document is organized into sections on quick installation, sensor wiring, grounding, power supply options, parameter setup, operation, technical data, error codes, extended protocol, and a FAQ. Detailed guidance is given for sensor placement, coupling agent use, signal quality checks, and troubleshooting common issues such as signal loss or incorrect current‑loop output. This manual is written in Chinese.
| Power supply | AC220V or DC24V |
|---|---|
| Battery operation time | 10 hours or more |
| Measurement principle | Time‑difference ultrasonic |
Check the M55 window to ensure the required current‑output mode is selected and not set to “closed current loop”.
If a static zero point was set while fluid was flowing, clear it using the M42/M43 settings to restore the original zero point.