Wellson WSRD200 Intelligent Radar Level Meter Installation Manual

WELLSONPRODUCTS WSRD200 intelligent radar level meter instruction manual, which introduces the measurement principle, input and output, application medium, product introduction, installation guide and other contents of this product.


Wellson WSRD200 Intelligent Radar Level Meter Installation Manual - cover page
Brand
WELLSON
Category
Surveying Equipment
Document type
User Manual
Language
Chinese
Pages
13
File format
PDF
File size
339 KB
Published
23 February, 2012
Updated
30 September, 2023
MD5 checksum
9B3928903BE45BD304FBF0F883B3A395

About this manual

This manual describes the WSRD200 series intelligent radar level meter, which can be used for liquid, solid, and slurry level measurement in tanks and pipelines. It explains the microwave measurement principle, signal processing, and how the device converts reflected signals into accurate level readings.

The document includes detailed installation instructions, internal mounting guidelines, measurement conditions, safety precautions, and technical specifications such as measurement range, temperature and pressure limits, accuracy, and signal output options. It also covers explosion‑proof (IP68) configurations and wiring requirements for 4‑20 mA HART communication. This manual is written in Chinese.

What's inside

  • Introduction
  • Installation Guide
  • Internal Installation
  • Measurement Conditions
  • Precautions
  • Technical Specifications
  • Explosion‑Proof Options
  • Signal Output

Specifications

Temperature range-40 °C to 130 °C (up to 250 °C for certain models)
Pressure range-1.0 bar to 40 bar
Accuracy< 0.19 % FS
Signal output4–20 mA HART
Explosion‑proof ratingIP68

Frequently asked questions

What is the minimum installation distance from the tank wall?

The sensor must be installed at least 200 mm away from the outer wall of the tank.

What signal output does the WSRD200 provide?

It provides a 4–20 mA HART output signal.

What is the measurement accuracy of the WSRD200?

The device achieves an accuracy of better than 0.19 % of full scale.

Can the WSRD200 be installed on both metal and non‑metal containers?

Yes, it can be installed on metal as well as non‑metal containers or pipelines.

Download PDF (339 KB)