Siemens Milltronics Pointek ULS200 Non-contact Ultrasonic Point Level Switch Product Leaflet


Siemens Milltronics Pointek ULS200 Non-contact Ultrasonic Point Level Switch Product Leaflet - cover page
Brand
Siemens
Category
Ultrasonic level meter
Document type
Product Leaflet
Language
Chinese
Pages
8
File format
PDF
Published
14 October, 2011
Updated
29 September, 2023
MD5 checksum
DB760009D36B6362AFFBF9746D54BB31

About this manual

The document describes the Pointek ULS200, a non-contact ultrasonic point level switch for detecting two levels in liquids, slurries and solids. It states detection ranges of 0.25–5 m for liquids and slurries and 0.25–3 m for bulk solids, with no contact between the sensor and the material.

It covers applications in food and beverage, power, grain, pulp and paper, storage tanks, water and wastewater, and cement. Technical data include two switch outputs, AC or DC power, polycarbonate or aluminum housings, Tefzel or Kynar-Flex sensor materials, Type 6/NEMA 6/IP67 protection, and ordering information. This manual is written in Chinese.

What's inside

  • Applications
  • Sonic Intelligence echo processing
  • Design and construction
  • Programming and use
  • Installation
  • Key features and benefits
  • Technical specifications
  • Ordering data

Specifications

Measurement range, liquids0.25 to 5 m
Measurement range, solids0.25 to 3 m
Repeatability0.25% of full scale
Power supply18–30 Vdc, max 3 W or 100–230 Vac, max 12 VA
AC output2 SPDT contacts, 5 A, 250 VAC
DC output2 transistor switches, 48 Vdc, max 100 mA or 2 SPDT contacts, 5 A, 48 Vdc
Enclosure ratingType 6/NEMA 6/IP67
Sensor materialTefzel®/Kynar-Flex®
Shipping weightPolycarbonate housing: 1.6 kg; aluminum housing: 2.3 kg
CertificationsCE, 3A, CSA NRTL/C, FM

Frequently asked questions

What level range can the Pointek ULS200 detect?

It detects solids up to 3 m and liquids or slurries up to 5 m without contacting the process medium.

How are the switch points programmed?

They are adjusted with two programming keys and an LCD under the housing cover.

Does the Pointek ULS200 require contact with the material?

No. The document states that it does not need to contact the process medium.