This is the Altivar 61 Variable Frequency Drive product catalog, suitable for 3-phase asynchronous motors with a power range of 0.75 to 630kW. This catalog contains a product selection guide, the Altivar 61 drive's features, operation, models, and options.
This manual covers the Altivar 61 variable‑frequency drive, which is rated from 0.75 kW up to 630 kW and is used in industrial and HVAC applications. It describes the device’s features, wiring, communication options, and EMC filtering.
The guide includes step‑by‑step installation instructions, safety functions such as Power Removal, configuration via PowerSuite, and diagnostic procedures. It also lists supported communication protocols (Modbus, CANopen, Ethernet TCP/IP, Profibus DP) and provides technical specifications and part numbers.
| Input voltage (single‑phase) | 200 V – 240 V |
|---|---|
| Input voltage (three‑phase) | 380 V – 480 V |
| Output frequency range | 0.5 Hz – 200 Hz |
| Rated motor power (example) | 22 kW |
| Rated motor voltage (example) | 400 V |
| Supported communication protocols | Modbus, CANopen, Ethernet TCP/IP, Profibus DP |
It supports Modbus, CANopen, Ethernet TCP/IP and Profibus DP.
The integrated “Power Removal” (断申) function stops the drive to protect against unintended restart.