PerkinElmer TPS334 Thermopile Detector Product Specification

TPS 334 is a thermopile sensor produced by PerkinElmer Company. It uses a 0.7 x 0.7 mm2 chip and a 30 kΩ thermistor as a temperature reference. The round window opening is equipped with a 5.5 µm longwave (standard) infrared filter. The sensor shows a flat sensitivity characteristic over the wavelength. TPS 334 can be equipped with a G9 (8.14 µm) filter for precision remote temperature sensing (TPS 334 G9).


PerkinElmer TPS334 Thermopile Detector Product Specification - cover page
Brand
Perkin
Category
Other
Document type
Datasheet
Language
English
Pages
32
File format
PDF
File size
2 MB
Published
24 September, 2011
Updated
01 October, 2023
Model
TPS 334
MD5 checksum
B25A5CADC1DFA9C30732755C64ECB492

About this manual

The TPS334 is a thermopile infrared detector housed in a TO‑5 package. It features a 0.7 × 0.7 mm absorber area, a 30 kΩ thermistor reference, and a standard 5.5 µm long‑pass infrared filter. The detector is suited for temperature‑measurement applications such as pyrometers and ear thermometers.

The document provides detailed electrical, optical, and mechanical characteristics, handling requirements, and quality‑system information. It also lists the typical performance parameters and environmental limits for the sensor.

What's inside

  • Scope
  • General Characteristics
  • Type Characteristics
  • Electrical Characteristics
  • Optical Characteristics
  • Filter Characteristics
  • Mechanical Drawing
  • Quality System

Specifications

Sensitive area0.7 × 0.7 mm
Window size25 mm diameter
DC sensitivity35 V/µW
Resistance75 kΩ
Noise38 nV/√Hz
NEP1.2 nW/√Hz
Detectivity (D*)0.6 × 10⁸ cm·Hz¹ᐟ²/W
Temperature coefficient of sensitivity0.02 %/K
Time constant25 ms
Operating temperature-40 °C to 100 °C
Thermistor resistance (25 °C)30 kΩ
Beta value3964 K
Field of view60° at 50 % points

Frequently asked questions

What is the sensitive area of the TPS334 detector?

The detector has a 0.7 × 0.7 mm absorbing area.

What temperature range can the TPS334 operate in?

It can operate from –40 °C to 100 °C.

What is the typical DC sensitivity of the TPS334?

The typical DC sensitivity is 35 V/µW.

What is the time constant of the TPS334 sensor?

The sensor’s time constant is 25 ms.

Download PDF (2 MB)

More Perkin Manuals


View all Perkin manuals →