The document describes the features and specifications of the rugged industrial multimeter.
This manual covers operation and maintenance of a rugged industrial digital multimeter with a 3-1/2 digit LCD readout (maximum reading 1999), automatic polarity, and DC/AC voltage, current, resistance, diode and continuity functions.
It includes front-panel descriptions, specifications, measurement procedures, precautions, battery and fuse replacement, and environmental and electrical ratings for indoor use.
| Display | 3-1/2 digit LCD, maximum reading 1999 |
|---|---|
| Polarity indication | Automatic |
| Measuring rate | 2.5 times per second, nominal |
| Auto power off | Approximately 30 minutes |
| Power | 9V battery (NEDA 1604, JIS 006P, IEC 6LF22) |
| Battery life | 300 hours (alkaline) |
| Dimensions without holster | 84 x 175 x 31 mm |
| Dimensions with holster | 95 x 192 x 50 mm |
| Weight without holster | 340 g (including battery) |
| Weight with holster | 550 g (including battery) |
| Operating temperature | 0°C to 45°C (below 75% R.H.) |
| Storage temperature | -20°C to 60°C (below 80% R.H.) |
| Pollution degree | 2 |
| Maximum altitude | 2000 m |
| DC voltage input impedance | 10 MΩ |
| DC voltage accuracy | ±(0.5% reading + 1 digit) |
| AC voltage accuracy | ±(1.25% reading + 4 digits), 40 Hz to 500 Hz |
| DC current accuracy (200 µA to 200 mA) | ±(1.0% reading + 1 digit) |
| DC current accuracy (20A range) | ±(2.0% reading + 3 digits) |
| AC current accuracy (200 µA to 200 mA) | ±(1.5% reading + 3 digits), 40 Hz to 500 Hz |
| AC current accuracy (20A range) | ±(2.5% reading + 3 digits), 40 Hz to 500 Hz |
| Resistance accuracy (lower ranges) | ±(0.75% reading + 1 digit) |
| Resistance accuracy (high range) | ±(1.5% reading + 5 digits) |
| Diode check accuracy | ±(1.5% reading + 5 digits) |
| Continuity buzzer threshold | Below 50 Ω |
| Fuse (mA/µA input) | 1A/500V fast blow |
| Fuse (20A input) | 16A/500V fast blow |
| Maximum rated voltage to earth | 1000V AC/DC |
Set the rotary switch to the required position, connect the black test lead to the COM terminal and the red lead to the VΩ terminal, then connect to the measuring points and read the display.
Between .500V and .900V.
After approximately 30 minutes when the rotary switch is not changed.
Disconnect the test leads, remove the three bottom screws, lift the case bottom, disconnect the old battery, connect a new 9V battery, and reassemble.