The Dell EqualLogic PS6210 Storage Arrays Hardware Owner's Manual describes the features and characteristics of the product.
This manual describes hardware installation, configuration, and use of Dell EqualLogic PS6210 storage arrays, including front and back panel features, drive handling, control module replacement, power supply and cooling maintenance, and troubleshooting.
It also covers bezel removal and installation, electrostatic discharge protection, array shutdown and restart, drive failure behavior, and Dell EqualLogic support contact information.
| Form factors | 2U chassis with 24 2.5-inch drives; 4U chassis with 24 3.5-inch drives |
|---|---|
| Control modules | Two hot-swappable Type 15 control modules |
| Memory per controller | 16 GB |
| Ethernet interfaces | Two pairs of 10 Gb/s dual-media interfaces (10GBASE-T/SFP+) |
| Ethernet auto-negotiation | Down to 1 Gb/s on 10GBASE-T ports only |
| Rack rails | Support for ReadyRails II |
A bezel key and a wrist grounding strap.
Unlock it with the bezel key, lift the left latch and swing the left side away, then lift the right side off the array.
Confirm the drive is identified as faulty in the GUI, console log, or monitoring log, then remove and replace it as soon as possible.
Call 800-945-3355.