This document provides a user's guide to Loctite® products, including threadlocking, thread sealing, porosity sealing, formed-in-place sealing, and gasketing.
This User's Guide serves as a supplemental service manual for maintenance professionals, detailing the proper selection and use of Loctite maintenance products. It covers preventative maintenance and repair techniques for various industrial equipment, aiming to reduce downtime and extend equipment life. The guide explains step-by-step procedures for using anaerobic resins, which convert from liquid to a solid in the absence of air.
| Temperature Range (222) | -55 to 150 °C |
|---|---|
| Temperature Range (263) | -55 to 150 °C |
| Temperature Range (290) | -55 to 150 °C |
| Viscosity (222) | 1,200 c.P |
| Primer for 222 | 7471 |
| Primer for 243 | 7471 |
Primers are required for inactive surfaces such as aluminum, stainless steel, magnesium, zinc, black oxide, cadmium, titanium, and others.
If initial pressure exceeds 1000 psi, wait 30 minutes before pressurizing.
No, do not use anaerobic threadlockers on most thermoplastics like ABS or PVC as softening or stress cracking may occur.
High strength threadlockers can be disassembled by applying heat at 250°C for 5 minutes.