User guide for selecting and using LOCTITE maintenance adhesives and sealants for threadlocking, sealing, gasketing, retaining, bonding, and repair.
This guide helps maintenance professionals select and use LOCTITE maintenance products. It covers anaerobic adhesives and sealants, primers, threadlocking, thread repair, thread sealing, porosity sealing, gasketing, retaining, disassembly, bonding, rustproofing, cleaning, troubleshooting, and ordering.
Step-by-step instructions are provided for applications such as thru and blind holes, studs, adjustment screws, pre-assembled fasteners, pipe fittings, flanges, keyed and shaft assemblies, housed components, and crack filling.
| Primer dry time | 30 seconds |
|---|---|
| Stud diameter for LOCTITE 277 Threadlocker | over 1 inch |
| Permanent stud installation cure time | 30 minutes |
| Wait before pressurizing above 1,000 psi | 30 minutes |
Primer is required for inactive surfaces such as pure aluminum, stainless steel, magnesium, zinc, black oxide, cadmium, titanium, nickel, and others.
LOCTITE 277 Threadlocker is recommended for studs over 1 inch in diameter.
Wait 30 minutes before pressurizing.
Apply heat to the screw with a soldering gun at 450°F.