CERN Power Converters for Particle Accelerators and the Large Hadron Collider Seminar

This document describes the power converters used in the Large Hadron Collider.


CERN Power Converters for Particle Accelerators and the Large Hadron Collider Seminar - cover page
Brand
CERN
Category
Power Management
Document type
Other
Language
English
Pages
43
File format
PDF
File size
4.4 MB
Published
18 November, 2023
Updated
18 November, 2023
MD5 checksum
863667E43F9CA80F2160B5344E2AEA02

About this manual

This seminar presentation by Davide Aguglia of CERN's TE/EPC Electrical Power Converter Group was given on 17 May 2016. It explains why power converters are needed in particle accelerators, reviews basic power electronics principles, and outlines design challenges and the converter group at CERN.

Design examples include LHC quadrupole power supplies with 13 kA output current and 18 V output voltage, and CLIC klystron modulators with 180 kV pulsed voltage, 160 A pulsed current, and 29 MW peak power.

What's inside

  • Why power converters in accelerators?
  • Basic principles in power electronics
  • Power converters design challenges at CERN
  • Design examples
  • Typical power converter design procedure
  • Electric Power Converter group in a nutshell
  • Conclusion

Frequently asked questions

How many dedicated power converters does CERN operate?

CERN operates about 6000 dedicated power converters for accelerator equipment.

What are the specifications of the LHC quadrupole power supplies?

They provide 13 kA output current at 18 V output voltage, with 24-hour current uncertainty of 5 ppm, 30-minute uncertainty of 3 ppm, and resolution below 1 ppm.

What is the peak power of the CLIC klystron modulators?

Each CLIC klystron modulator has a peak output power of 29 MW.