The document describes how to use GC EQUIA Forte®II for Class II cavity filling.
This two-page technique guide outlines Class II cavity preparation and restoration steps for GC EQUIA Forte II, including optional cavity conditioner application, mixing, capsule priming, light curing, packing, contouring, finishing, and application of EQUIA Forte Coat.
| Cavity conditioner application time | 10 sec |
|---|---|
| Mixing time | 10 sec |
| Working time | 1 min 15 sec from start of mix |
| Capsule priming | Click twice |
| Light curing time | 20 sec |
| Dispensing time | Within 10 sec |
| Final finishing time | After 2 min 30 sec from start of mix |
Apply CAVITY CONDITIONER for 10 seconds.
The working time is 1 minute 15 seconds from the start of mix.
Light cure the restoration for 20 seconds.
Final finishing is performed after 2 minutes 30 seconds from the start of mix.