The DB-1 demonstration board manual introduces the product's features and specifications.
The SONEL DB-1 Demonstration Board is a training tool designed for electrical installation and grounding measurement courses. It allows users to simulate various measurements required by IEC 60364-6-61 standards, including loop impedance, earth resistance, and insulation resistance, by activating specific fault conditions via front panel switches.
The device features a front panel with power inputs, measurement terminals, and switches to simulate irregularities such as high earth resistance, low insulation resistance, and excessive loop impedance. It is intended for use by qualified personnel in schools, training centers, and distribution points to demonstrate safe and accurate measurement procedures. This manual is written in Spanish.
| Nominal Voltage | 230 V |
|---|---|
| Frequency | 50 Hz |
| Fuses | F4A 250 V |
| Allowed Fuses | T3,14 A 250 V |
| High Earth Resistance Simulation | 1 kΩ |
| Low Insulation Resistance L-PE | 200 kΩ |
| Low Insulation Resistance L-N | 100 kΩ |
The board can only be used by qualified persons authorized to work with electrical installations or under their supervision.
Setting the ZL switch to red simulates an excessively high loop impedance, allowing the measurement of this fault condition.
No, it is prohibited to use the device in networks or equipment where there is a risk of explosion or fire.