LA series filters are high-flow filtration equipment with permanent filter media for removing suspended impurities and colloids, and are an indispensable element in water purification.
This document is the instruction manual for Jacuzzi LA series pool filters, models LA160, LA192, LA225 and LA250. It covers filter description, dimensions, civil, hydraulic and electrical installation, pool filling and related tables.
The filters are high-flow units with permanent filter media for removing suspended impurities and colloids. The manual specifies tank dimensions, flow rates, sand quantities, pool volumes by recirculation time, piping sizes and electrical recommendations. This manual is written in Spanish.
| Filtration rate | 1.450 m3/m2/day (as printed) |
|---|---|
| External tank diameter | 406 mm (LA160), 482 mm (LA192), 571 mm (LA225), 634 mm (LA250) |
| Total filtration area | 0.12 m2 (LA160), 0.19 m2 (LA192), 0.25 m2 (LA225), 0.31 m2 (LA250) |
| Flow rate | 5.7 m3/h (LA160), 9.1 m3/h (LA192), 12.0 m3/h (LA225), 14.8 m3/h (LA250) |
| Sand quantity | 75 kg (LA160), 100 kg (LA192), 125 kg (LA225), 175 kg (LA250) |
| Pool volume at 6 h recirculation | 34 m3 (LA160), 55 m3 (LA192), 72 m3 (LA225), 89 m3 (LA250) |
| Overall height (dimension C) | 822 mm (LA160), 911 mm (LA192), 924 mm (LA225), 1038 mm (LA250) |
| Suction connection | 1 1/2 in |
| Pump discharge connection | 1 1/2 in (LA160-LA225), 2 in (LA250) |
| Selector valve connection | 1 1/2 in |
| Filter head loss at nominal flow | 2.5 mca |
| Maximum water velocity | 3 m/s in return piping; 1.8 m/s in suction piping |
| Electrical supply | Single-phase motors 220 V; three-phase motors 380 V |
| Pump elevation | Preferably below water level; maximum 1 m above water level |
| Flow-rate basis | 1.150 m3/m2/day maximum allowed by norm in Chile |
It is 6 hours for pools with minimum depth up to 0.60 m and 8 hours for pools with minimum depth greater than 0.60 m.
Do not connect the public water supply directly to the circulation system; use a tap about 20 cm above the pool edge, a hose from a distant tap, or a regulating tank.
Protect the motor circuit with a thermomagnetic breaker and differential protection; three-phase motors should also be protected against overload by a thermal relay.
The water velocity should not exceed 3 m/s in return piping and 1.8 m/s in suction piping.