The Xgard Bright Gas Detector User Manual provides information on the features, specifications, installation, and operation of the Xgard Bright Gas Detector.
This user and operator manual covers the Crowcon Xgard Bright and Xgard IR gas detectors with display and relays. It is document M079910 issue 3, dated April 2019, and is provided in multiple languages including English, French, German, Spanish, Italian, Dutch, Polish, and Portuguese.
Contents include diagrams, certification labels, dimensions, and an exploded view, followed by introduction, safety information, storage instructions, installation, operation, and specification sections. Installation covers hazardous area use, location, mounting, internal electrical connections, cabling, and earthing requirements.
| Housing material | ADC 12 aluminium alloy |
|---|---|
| Dimensions | 156 x 166 x 109 mm |
| Weight | 1 kg (2.2 lbs) |
| Ingress protection | IP65 & IP66 |
| Cable entry | 2x M20 |
| Supply voltage | 10-30 V DC, 3 W max |
| Electrical output | 4-20 mA sink or source, RS-485 Modbus RTU, HART optional |
| Operating temperature | -40 °C to +70 °C |
| Humidity | 0 to 95 % RH, non-condensing |
| Certifications | ATEX and IECEx |
-40 °C to +70 °C (-40 °F to 158 °F).
ATEX and IECEx certifications for use in Zone 1 and Zone 2.
10-30 V DC with a maximum of 3 W.
IP65 and IP66 with the weather protection cap.