Crowcon Gas-Pro Multi-Gas Detector User Manual

The Gas-Pro is a multi-gas detector that can detect H2S, CO and CH4 gases. It has the following features:


Crowcon Gas-Pro Multi-Gas Detector User Manual - cover page
Brand
Crowcon
Category
Monitoring Equipment
Document type
User Manual
Language
Portuguese
Pages
57
File format
PDF
File size
5.1 MB
Published
06 November, 2023
Updated
06 November, 2023
MD5 checksum
68BC19C03EA1AAE30E95471D9D1570CC

About this manual

The Gas-Pro is a portable personal monitor that can detect up to five gases and may include an internal pump. It is certified for use in hazardous areas and provides audible, visual and vibration alarms, a top-mounted backlit display and single-button operation.

This manual covers preparation, operation, alarms, Gas-Pro functions, Tank Check Mode, gas testing and calibration, icon overview, maintenance, PC interface, accessories, technical specifications, troubleshooting and appendices. This manual is written in Portuguese.

What's inside

  • Preparation
  • Operation
  • Alarms
  • Gas-Pro Functions
  • Tank Check Mode
  • Gas Testing and Calibration
  • Maintenance
  • PC and Portables-Pro Interface
  • Technical Specifications
  • Troubleshooting

Specifications

Gas detection capacityUp to 5 gases
Internal pumpOptional
AlarmsAudible and visual alarms
Vibration alarmIncluded
DisplayTop-mounted backlit display
ControlsSingle-button operation
Operating temperature-20 to +55 C
Operating pressure80 to 110 kPa
Oxygen levelTypically 21% v/v
Power supplyNominal 6.5 V, maximum 9.1 V
Communication interfaceNominal 3.0 V TTL, maximum 9.1 V
Charging temperature0 to 40 C
Hazardous area useZones 1 and 2
Battery charging locationNon-hazardous (safe) areas only

Frequently asked questions

How many gases can the Gas-Pro detect?

The Gas-Pro is a portable monitor capable of detecting up to five gases.

Does the Gas-Pro have a vibration alarm?

Yes, in addition to audible and visual alarms, it also has a vibration alarm.

What is the operating temperature range?

The device is intended for use at ambient temperatures from -20 C to +55 C.

Can the battery be charged in a hazardous location?

No, the rechargeable battery must be charged only in non-hazardous (safe) areas.