Raycus RFL-C2000 Continuous Fiber Laser User Manual

This product is a 2000W small-sized fiber laser with the advantages of small size, light weight, good beam quality and high efficiency.


Raycus RFL-C2000 Continuous Fiber Laser User Manual - cover page
Brand
Raycus
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
36
File format
PDF
File size
7.5 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
9125E845AC7A48BB1E31EA7F70C936F2

About this manual

The Raycus RFL-C2000 is a 2000W continuous fiber laser designed for industrial applications such as welding, 3D printing, and laser research. It features high beam quality, high reliability, power stability, and maintenance-free operation with a wavelength of 1080±5 nm and modulation frequency of 50-5000 Hz.

The manual provides comprehensive safety guidelines including Class 4 laser classification per EN 60825-1, electrical safety requirements (380V AC, grounding), optical safety precautions, and detailed installation procedures for the water-cooled unit. It covers control interfaces (RS-232, AD, Ethernet), operation modes (internal, external, AD), startup/shutdown sequences, alarm handling, and warranty terms. This manual is written in Chinese.

What's inside

  • Safety Information
  • Product Introduction
  • Installation
  • Product Usage
  • Common Alarms and Handling
  • Warranty and Repair Process

Specifications

Rated Output Power2000 W
Operating ModeContinuous/Modulation
Center Wavelength1080±5 nm
Power Adjustment Range10~100%
Output Power Instability<±1.5%
Modulation Frequency50-5000 Hz
Red Guide Laser Power0.5~1 mW
BPP (Beam Parameter Product)1.6-2 mm×mrad
Half-angle Divergence0.06-0.08 rad
Fiber Core Diameter50 μm (20, 100, 200 optional)
Output Cable Length20 m (customizable)
Operating Voltage380±15% V AC, 50/60Hz
Max Power Consumption6100 W
Control MethodsRS-232/AD/Ethernet
Dimensions (W×D×H)414×686×158 mm (with handle)
Weight<50 kg

Frequently asked questions

What is the laser safety class of the Raycus RFL-C2000?

The Raycus RFL-C2000 is classified as a Class 4 laser product according to EN 60825-1.

What are the power supply requirements for the RFL-C2000?

The RFL-C2000 requires 380±15% V AC, 50/60Hz with a power capacity of 6.1 kW.

What control interfaces does the RFL-C2000 support?

The RFL-C2000 supports RS-232, analog (AD), and Ethernet (TCP/IP) control interfaces.

What is the operating temperature range for the RFL-C2000?

The operating environment temperature range is 10~40°C with humidity below 95%.

Download PDF (7.5 MB)