This manual provides safety information, installation instructions, operation procedures, and troubleshooting for the Raycus 1500W continuous fiber laser.
The document is a user manual for the Raycus RFL-C1500H continuous fiber laser. It covers essential topics including safety warnings regarding Class 4 laser radiation, product features such as high beam quality and efficiency, and specific operating environments requiring temperatures between 10°C and 40°C. This manual is written in Chinese.
| Rated Output Power | 1500 W |
|---|---|
| Center Wavelength | 1080±5 nm |
| Power Regulation Range | 10~100 % |
| Modulation Frequency | 50~20,000 Hz |
| Max Power Consumption | 5500 W |
| Operating Voltage | 220±10% VAC, 50/60Hz |
| Operating Temperature | 10~40 ℃ |
The device belongs to Class 4 laser instruments according to European standard EN60825-1.
The minimum bending radius must not be less than 20cm during transport/storage and 30cm when emitting light.
The rated output power supports a continuous operation time of at least 5 hours.