The SMX Series Magnetic Drive Pump Manual explains how to properly handle, operate, maintain, inspect, and troubleshoot the pump.
This document serves as the instruction manual for the Iwaki SMX Series magnetic drive pump. It covers essential topics including unpacking and inspection, model identification codes, technical specifications, and descriptions of the main unit components and labels. The guide details the correct handling procedures, such as avoiding dry running and proper priming, to ensure optimal performance and longevity. This manual is written in Spanish.
| Liquid Temperature Range | 32 - 176°F (0 - 80°C) |
|---|---|
| Maximum Specific Gravity | 1.2 |
| Maximum Viscosity | 30 cP |
| Maximum Dry Run Time | 1 hour |
The required volume depends on the model: 0.80 gal (3L) for SMX-(F)22, 1.11 gal (4.2L) for SMX-(F)44, and 1.43 gal (5.4L) for SMX-(F)54.
Yes, models with 'CA' and 'CF' bearing systems can tolerate dry running for up to one hour, but it is recommended to let the pump cool for at least 20 minutes before introducing fluid.
The switching frequency should be limited to six times or less per hour to avoid shortening the service life.