Instruction Manual for IWAKI Magnet Gear Pump MDG-M4 (built-in type)
This instruction manual is for the IWAKI MDG-M4 built-in type magnet gear pump. It covers safety instructions, inspection after unpacking, the pump's operating principle, identification codes, parts and structure, precautionary measures, installation, piping and wiring, operation, maintenance and inspection, disassembling and reassembling, troubleshooting, performance and sizes, and repair service.
The manual describes the pump as having a pair of gears driven by a magnet coupling and a casing in which the gears are fitted exactly. Liquid enters from the IN side, is carried in the grooves between the gear teeth, and is forced out the OUT side by gear meshing.
| Maximum discharge pressure | 0.6 MPa |
|---|---|
| Connection | 1/4NPT |
| Line voltage | AC220–240 V single phase |
| Liquid temperature range, Type S | 0 to 50°C |
| Liquid temperature range, Type T | 0 to 95°C |
| Liquid viscosity, Type S | below 30 mPa·s |
| Liquid viscosity, Type T with 100 W motor | below 80 mPa·s |
| Liquid viscosity, Type T with 150 W motor | below 200 mPa·s |
Check that the pump model, discharge, discharge pressure, voltage and other nameplate items match your order.
The manual gives the Type T liquid temperature range as 0 to 95°C.
No. The manual states that the power cable cannot be replaced and that the pump unit itself must be replaced in that circumstance.
Thoroughly wash the inside before shipping so residual liquid does not flow out in transit.