perma-tec perma NOVA Installation Guide

perma NOVA is a single-point lubrication system. You must use a separate lubrication system for each lubrication point.


perma-tec perma NOVA Installation Guide - cover page
Brand
perma-tec
Category
Industrial Robot
Document type
Installation Guide
Language
English
Pages
12
File format
PDF
File size
2.9 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
6767D1395CAA064833CCA162D5E24703

About this manual

This installation guide covers the setup of the perma NOVA single-point lubrication system. It details preparation steps, including cleaning the lubrication point and selecting the appropriate lubricant. The guide explains different mounting options, such as direct mounting for dry environments and remote mounting with tubes for high-temperature or hazardous areas.

What's inside

  • Basic Guidelines
  • Mounting types
  • Preparation of lubrication point
  • Pressure testing
  • Activation und installation
  • Identification of lubrication system

Specifications

Connection threadBSP R¼ male thread
Tube inside diameterat least 6 mm
Max tube length (Grease SF01)1 m
Max tube length (Oil SO32)3 m
Required counter pressure range0.5 - 2 bar
Max injection pressure6 bar

Frequently asked questions

What is the connection thread size for perma NOVA?

The connection thread is a BSP R¼ male thread.

When should remote mounting be used instead of direct mounting?

Remote mounting is recommended if the ambient temperature is permanently higher than +60 °C, the point is exposed to high vibrations, or access is difficult or dangerous.

What lubricant should be used for pressure testing?

You must use the same lubricant for both prefilling and the pressure test as the one contained in the lubrication system.

What happens if the pressure exceeds 6 bar during testing?

The lubricator will shut off automatically.