This installation guide from perma-tec describes how to install the perma PRO / PRO C MP-6 lubrication system and how to avoid basic mounting errors. It is meant to be used together with the operating instructions, and the drawings it contains are examples only, since many other mounting possibilities exist depending on local conditions.

The guide covers basic guidelines for positioning and securing the system, the mounting types and scheme, mounting with the mounting bracket PRO 101568 and optional protection boxes, direct versus separate mounting of the PRO MP-6 distributor, preparation of the lubrication point with prefilled accessories and tubes, and pressure testing with the Accessory Set for pressure test (101480), including the step-by-step pressure test procedure.

What's inside

  • Basic guidelines
  • Mounting types
  • Scheme
  • Mounting
  • Direct vs separate mounting of PRO MP-6 distributor to lubrication system
  • Preparation of lubrication point
  • Pressure testing
  • Pressure test procedure
  • Settings and display
  • Identification of lubrication system

Specifications

Recommended hose inner diameterat least 5 mm
Minimum counter pressure rating of accessories and tubes25 bar
Max. tube length per outlet5 m
Max. pressure load of perma PRO25 bar
PA tube dimensions and temperatureoØ 8 mm x iØ 5 mm, up to +100 °C
Heavy Duty hose dimensions and temperatureoØ 16 mm / iØ 9.5 mm, up to +100 °C
Threadlocker for metal to metal connectionsLOCTITE 243 (Art. No. 110278)

Frequently asked questions

How long can the tube of each outlet be?

The tube length of each outlet cannot exceed 5 m; the actual length depends on ambient temperature, type of tube and type of grease used.

How do I trigger an additional discharge during the pressure test?

Press both buttons at the same time and hold for at least 4 seconds; the system then performs an additional discharge automatically.

What happens if the pressure exceeds 25 bar during the additional discharge?

The lubrication system shuts off automatically. If the injection pressure exceeds 25 bar and does not decrease, a different lubricant must be selected or the lube point purged with a mechanical grease gun.

Where can the mounting bracket PRO 101568 be used?

It can be used to secure a perma PRO MP-6 / PRO C MP-6, perma PRO / PRO C or a perma distributor PRO MP-6.