Installation guide for the perma PRO / PRO C MP-6 lubrication system: basic guidelines, mounting types, lubrication point preparation and pressure testing.
This installation guide from perma-tec describes how to install the perma PRO / PRO C MP-6 lubrication system and how to avoid basic mounting errors. It is meant to be used together with the operating instructions, and the drawings it contains are examples only, since many other mounting possibilities exist depending on local conditions.
The guide covers basic guidelines for positioning and securing the system, the mounting types and scheme, mounting with the mounting bracket PRO 101568 and optional protection boxes, direct versus separate mounting of the PRO MP-6 distributor, preparation of the lubrication point with prefilled accessories and tubes, and pressure testing with the Accessory Set for pressure test (101480), including the step-by-step pressure test procedure.
| Recommended hose inner diameter | at least 5 mm |
|---|---|
| Minimum counter pressure rating of accessories and tubes | 25 bar |
| Max. tube length per outlet | 5 m |
| Max. pressure load of perma PRO | 25 bar |
| PA tube dimensions and temperature | oØ 8 mm x iØ 5 mm, up to +100 °C |
| Heavy Duty hose dimensions and temperature | oØ 16 mm / iØ 9.5 mm, up to +100 °C |
| Threadlocker for metal to metal connections | LOCTITE 243 (Art. No. 110278) |
The tube length of each outlet cannot exceed 5 m; the actual length depends on ambient temperature, type of tube and type of grease used.
Press both buttons at the same time and hold for at least 4 seconds; the system then performs an additional discharge automatically.
The lubrication system shuts off automatically. If the injection pressure exceeds 25 bar and does not decrease, a different lubricant must be selected or the lube point purged with a mechanical grease gun.
It can be used to secure a perma PRO MP-6 / PRO C MP-6, perma PRO / PRO C or a perma distributor PRO MP-6.