The RibEye Multi-Point Deflection Measurement System is a device used to measure the deflection of ribs. It can be mounted on an ATD and controlled by software. The device can measure the deflection of the ribs under different loads and can store the data in flash memory.
The Polar RibEye is a multi-point deflection measurement system designed for the Polar ATD. It mounts to the lower spine of the dummy and uses six LEDs mounted on ribs 4, 5, and 6 to record X and Y positions at a sample rate of 10 kHz. The system records up to 30 seconds of data in dynamic random access memory (D-RAM) and copies 2 seconds to flash memory after a test.
| Sample Rate | 10 kHz |
|---|---|
| RAM Data Storage | 30 seconds |
| Flash Memory Storage | 2 seconds |
| Power Requirement | +10 to +15 VDC |
| Connector Type | 25-pin Micro-D |
Select the Ethernet connection option in the software and enter the RibEye's IP address, or click the 'Find RibEyes' button to search the LAN.
The trigger should be held at ground for no trigger, and a positive pulse greater than 6 volts DC will cause a trigger on the rising edge.
The LEDs must be plugged into the connector in the order listed in Table 1, matching specific rib numbers and locations.