TFM TFM Ultrasonic Flow Meter User Manual

Ultrasonic Flow Meter User Manual, Model: TFM, Features: High measurement accuracy, Good stability, Strong reliability, Wide range of applications.


TFM TFM Ultrasonic Flow Meter User Manual - cover page
Brand
TFM
Category
Other Electronics
Document type
User Manual
Language
English
Pages
37
File format
PDF
File size
4.4 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
D63328655CBEA0F425F6A6BA02730E4F

About this manual

This manual provides instructions for the TFM TFM ultrasonic flow meter, a wall-mounted device designed for long-term flow measurement in closed conduits. It utilizes a transit-time measuring principle with non-contacting, clamp-on transducers suitable for various liquids including water, oil, and chemicals. The device supports pipe sizes from DN15mm to DN6000mm and offers features such as data recording, multiple output signals, and bi-directional flow measurement.

What's inside

  • Introduction
  • Installation and Measurement
  • Wiring diagram
  • Keypad
  • Menu Windows
  • Transducers Installation
  • Troubleshooting
  • Specifications
  • Typical application
  • Product Identification

Specifications

AccuracyBetter than ±1%
RepeatabilityBetter than 0.2%
Measurement Period500ms
Pipe Size RangeDN15mm to DN6000mm
Power SupplyAC220V or DC24V
Temperature Range (Standard)-30˚C - 90˚C
ProtocolsMODBUS, M-BUS, Fuji extended protocol

Frequently asked questions

What is the flow measurement principle of the TFM meter?

It utilizes a transit-time measuring principle with two transducers that function as both ultrasonic transmitters and receivers.

What liquids can the TFM ultrasonic flow meter measure?

It can measure pure liquids, liquids with small quantities of tiny particles, sewage, oil, chemicals, and plant effluent.

How do I enter a specific menu window directly?

Press the MENU key followed by the two-digit number corresponding to the desired menu window.

What are the installation requirements for straight pipe sections?

The upstream section must be beyond 10D and the downstream section beyond 5D, where D is the pipe diameter.