PowerSafe® SBS® EON Technology® solutions are well proven in stand by and cyclic applications, recent developments have focused on improving robustness in harsh environments and challenging operating conditions, so that today EON Technology now has higher cyclic performance, improved endurance at high temperature and the ability to operate in partial state of charge, providing that the operating conditions are well understood.
This guide covers general operating instructions and cyclic operation guidelines for PowerSafe SBS EON Technology monoblocs and cells used in off-grid hybrid reserve power applications. It addresses operating temperature, storage, freshening charge, commissioning, fast charging, charging current limits, disposal, and controlled full or partial state of charge operation.
The document includes charging parameters for optimized life and performance, storage time and open-circuit voltage relationships by temperature, and definitions of controlled full and partial state of charge operating modes.
| Operating temperature range | -40°C to +50°C |
|---|---|
| Shelf life at 20°C | 2 years |
| Freshening charge trigger | OCV approaches 2.10 V/cell |
| Freshening charge voltage | 2.29 to 2.40 V/cell |
| Freshening charge duration | 24 hours |
| Commissioning charge | 24 hours at 2.40 V/cell, no load |
| Fast charge voltage | 2.40 V/cell at 20°C |
| Minimum charging current | Load + 0.1C10 A |
| Recyclability | Recyclable |
The recommended range is -40°C to +50°C, with optimum life and performance at +20°C.
A freshening charge is required when the open-circuit voltage approaches 2.10 volts per cell or maximum storage time is reached, whichever occurs first.
The battery must receive a 24-hour charge at a voltage equivalent to 2.40 volts per cell with no load connected.
Yes, they are recyclable and end-of-life batteries must be disposed of by a licensed battery recycler in compliance with local and national laws.