Peak Scientific Solaris XE Nitrogen Generator User Manual

This document is the Solaris XE User Manual, which introduces the features and characteristics of the Solaris XE.


Peak Scientific Solaris XE Nitrogen Generator User Manual - cover page
Brand
Peak Scientific
Category
Generator
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1.8 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
6187544D95F14FCAC4115977FF7265B6

About this manual

Peak Scientific's Solaris XE User Manual is a reference document for end users of the Solaris XE nitrogen generator. It covers safety notices, declarations, technical specifications, unpacking, installation, air purity requirements, startup and pressure setting, service, cleaning, and troubleshooting.

The manual lists operating environment limits, inlet air pressure and quality, outlet flow and purity, electrical requirements, dimensions, and weights for the generator.

What's inside

  • Technical Specification
  • Unpacking
  • Fittings Kit Contents
  • Installation
  • Air Purity
  • Start-Up Sequence
  • Service Requirements
  • Cleaning
  • Troubleshooting

Specifications

Minimum Operating Ambient Temperature5°C (41°F)
Maximum Operating Ambient Temperature35°C (95°F)
Maximum Altitude2000 m
Maximum Relative Humidity80% Non-Condensing
Minimum Storage Temperature-20°C (-4°F)
Maximum Storage Temperature60°C (140°F)
Inlet Air Pressure5.51 - 9.99 bar (80 - 145 psi)
Minimum Air Inlet Flowup to 100 L/min
Minimum Air Inlet QualityISO 8573-1:2010 Class[1.4.1]
Maximum Output Pressure116 psi / 7.99 bar (variable)
Maximum Outlet Flow Rateup to 35 L/min
Purity95-99.5% N2
Particles<0.01µm
PhthalatesNONE
Suspended LiquidsNONE
Gas Outlets1
Start-Up Time For Purity5 mins
Voltage100-230v
Frequency50/60 Hz
Current0.10A
Input ConnectionC14 Plug
Power Cord (Supplied)C13 Socket to Local Connection
Pollution Degree2
Insulation CategoryII
Fuses (UK Only)13A BS1362
General Dimensions (WxDxH)34.3 x 65.5 x 15.6 cm (13.5 x 25.78 x 6.14 in)
Generator Weight15.1 kg (33.2 lbs)
Shipping Weight18 kg (39.6 lbs)
Max Weight Bearing100 kg (220 lbs)

Frequently asked questions

What air quality is required at the Solaris XE inlet?

The minimum air inlet quality is ISO 8573-1:2010 Class[1.4.1].

How long does the Solaris XE take to reach purity at startup?

The start-up time for purity is 5 mins.

What is the maximum outlet flow rate of the Solaris XE?

The maximum outlet flow rate is up to 35 L/min.

How many people are needed to unpack the Solaris XE?

It requires two people to remove the unit from the shipping crate.

Download PDF (1.8 MB)

More Peak Scientific Manuals