This document provides the instruction manual for Alfa Laval Unique Single Seat Valve - Long Stroke Shut-off Valve and Change-over Valve.
This manual provides complete instructions for the Alfa Laval Unique Single Seat Valve Long Stroke series, including both shut-off and change-over valve configurations. It covers safety precautions, installation steps, operation guidelines, troubleshooting, cleaning recommendations, maintenance procedures, technical data, and parts lists with service kits.
The document emphasizes critical safety warnings such as never exceeding 3 bar support air pressure, avoiding water hammering, and never dismantling the valve under pressure or when hot. It includes detailed unpacking, welding, and assembly instructions, along with specific torque values for different actuator generations and genuine spare part numbers.
| Maximum recommended support air pressure | 3 bar / 43.5 PSI |
|---|---|
| Maximum product pressure | 10 bar / 145 PSI |
| Steel adapter tightening torque (actuators 2005-2018) | 30 Nm |
| Steel adapter tightening torque (actuators 2019 onward) | 15 Nm |
| Air relief fitting article number | 9611995903 |
Alfa Laval recommends not exceeding 3 bar (43.5 PSI) support air on the spring side.
The product pressure must not exceed 10 bar (145 PSI).
The tightening torque is 15 Nm for actuators with serial numbers from 6000000 to 7000000 and from 60000000000 to 70000000000.