This manual is a instruction manual for the rotary lobe pumps produced by Alfa Laval Eastbourne, Alfa Laval Ltd. The manual mainly introduces the model, safety, installation, maintenance and other information of the pump.
This document is the original instruction manual for the Alfa Laval SX Range of rotary lobe pumps, covering models from series SX1 to SX7. It details the declaration of conformity, general information regarding pump duties and noise levels, and comprehensive safety precautions for installation and operation.
The guide provides step-by-step instructions for unpacking, handling, and storage, followed by system design and installation procedures. It includes specific guidance on flushing seal arrangements, cleaning in place (CIP), maintenance schedules, disassembly, assembly, and primary seal removal. Troubleshooting advice and technical data, including pump head clearance information, are also included.
The pump can produce sound pressure levels in excess of 80dB[A].
The pump must be rotated by hand weekly to prevent bearing damage.
Only cleaning fluids below PH 8 are permitted for external cleaning.