Kunlun Coast JZH-102 Wireless Carbon Dioxide Sensor User Manual

The JZH-102 is a wireless carbon dioxide sensor that uses 2.4G DSSS spread spectrum technology, has strong anti-interference ability, and is suitable for indoor environmental measurement, agricultural greenhouse intelligent management, etc.


Kunlun Coast JZH-102 Wireless Carbon Dioxide Sensor User Manual - cover page
Brand
Kunlun Coast
Category
sensor
Document type
User Manual
Language
Chinese
Pages
3
File format
PDF
File size
473 KB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
53C6938FD5EB5EE4C590ED7AF978B806

About this manual

The Kunlun Coast JZH-102 is a wireless carbon dioxide sensor with integrated collection and transmission, selectable physical channels and network IDs, and is intended for indoor environment measurement and agricultural greenhouse management.

The manual describes its technical parameters, dimensions, precautions, installation, parameter settings, display indications, use of the ZigBee network configurator, and reference to the communication protocol. This manual is written in Chinese.

What's inside

  • Overview
  • Technical parameters
  • Dimensions
  • Precautions
  • Installation
  • Parameter settings
  • Display description
  • ZigBee network configurator usage
  • Communication protocol

Specifications

Power supplyDC 12 V (9 V to 28 V)
Working frequency band2.4 GHz
Network protocolZigBee PRO
Communication distanceAt least 800 m in open environment
Channels16 (0 to F)
Network ID0x0000 to 0xFFFE
Baud rate38400 bps
Measurement range0 ppm to 2000 ppm (optional 0-5000 ppm, 0-10000 ppm)
Accuracy±(40 ppm + 3% F.S.) at 25°C
Resolution1 ppm
Startup time5 s or less
Working time5 s or less
Sleep time60 to 65535 s (default 60 s)
Data transmission formatActive report
Working environment0°C to 50°C; 5%RH to 95%RH (non-condensing)
Storage conditions0°C to 50°C; 5%RH to 95%RH (non-condensing)
Power consumptionMaximum 30 mA or less
Installation methodWall mounting
HousingABS, 180 mm x 130 mm x 53 mm
Product weight380 g or less

Frequently asked questions

What is the communication distance of the JZH-102?

The communication distance is at least 800 m in an open environment.

What CO2 measurement range does the sensor support?

The range is 0 ppm to 2000 ppm, with optional 0-5000 ppm and 0-10000 ppm ranges.

How is the JZH-102 installed?

It uses wall mounting installation.

What network protocol does it use?

It uses the ZigBee PRO protocol.