About this manual

This document is an installation manual for the outdoor unit of an air conditioner that uses R410A refrigerant. The main body is written in traditional Chinese, while the multilingual cover also carries the title in other languages such as Vietnamese (HƯỚNG DẪN LẮP ĐẶT) and Indonesian (PANDUAN PEMASANGAN, UNIT LUAR), and it is intended for authorized service personnel. The document carries part number 9377863294.

The manual explains that it only covers installation of the outdoor unit and refers readers to the indoor unit's own installation manual. It covers safety precautions, notes that the unit is not explosion-proof and must be installed by authorized personnel, and explains R410A-specific requirements such as dedicated tools, minimum copper pipe wall thickness, refrigerant piping length limits, additional refrigerant charge, pipe diameters, and electrical wiring with a dedicated circuit breaker and earth leakage breaker. This manual is written in Chinese.

What's inside

  • Safety precautions
  • About this unit
  • Choosing the installation location
  • Installation diagram
  • R410A dedicated tools
  • Accessories
  • Refrigerant piping length limits
  • Additional refrigerant charge
  • Refrigerant piping sizes
  • Electrical wiring and circuit breaker

Specifications

RefrigerantR410A
Rated voltage230 V (50 Hz)
Operating voltage198-264 V
Minimum copper pipe wall thickness0.8 mm
Max piping length / height difference (24 type)30 m / 20 m
Max piping length / height difference (12, 18 type)25 m / 15 m
Additional refrigerant charge20 g per meter beyond 15 m
Earth leakage breaker30 mA, 0.1 s or less

Frequently asked questions

Which refrigerant does this outdoor unit use?

It uses the new R410A refrigerant, and dedicated R410A tools, piping and flare nuts must be used instead of parts made for R22.

Can I reuse the existing piping and flare nuts from an R22 unit?

No. Reusing R22 piping and flare nuts would raise the pressure inside the refrigerant circuit and cause damage or injury, so R410A-dedicated materials must be used.

How much additional refrigerant charge is needed for longer piping?

The unit is pre-charged for 15 m of piping; beyond that, additional refrigerant is charged at a standard of 20 g per meter according to the table.

How long should I wait after switching off the power before touching electrical parts?

Wait at least 10 minutes after the power is off before touching electrical parts, otherwise an electric shock may occur.