This paper introduces a method for detecting the torque of a ship unloader brake based on a frequency converter. The method realizes the visual detection of the brake torque by reading the parameters of the frequency converter and the overload protection function, which facilitates the daily maintenance of the brake and improves the safety of the equipment.
This is a Chinese technical journal article (中国机械, 2022, No. 10) by Zhang Biao and Wang Jie of Cangzhou Huanghua Port Ore Port Co., Ltd. It addresses the problem that ship unloader brake torque is normally adjusted only according to the brake manual, without direct measured data, and proposes a visual torque detection method based on reading converter parameters and using the overload protection function.
The article describes the unloader's drive system (hoisting/closing/trolley, boom luffing, gantry travel and material mechanisms), the Siemens S7-400 PLC, SIMOTION D435 and SINAMICS S120 hardware configuration, parameter settings (DDS/CDS switching, torque limitation), axis commissioning with the SCOUT tool, and the actual brake torque test procedure, in which the motor is driven at low speed against the locked brake and held for about 30 seconds to confirm the braking torque meets the design requirement. This manual is written in Chinese.
| Hoisting/closing motor power | 500 kW |
|---|---|
| Luffing motor power | 200 kW |
| ALM line module power | 900 kW |
| Inverter power (main drives) | 560 kW |
| High-speed brake set torque | 2570 Nm |
| Low-speed brake torque per group | 1350 Nm |
| Torque limit (DDS=2) | ±2600 Nm |
| Torque limit (DDS=1) | ±9600 Nm |
The test uses the SIMOTION SCOUT engineering and commissioning tool, whose configuration, programming, testing and debugging tasks are all handled graphically.
The converter output torque is set to the brake's rated torque and the motor is driven at low speed against the locked brake; if the motor does not rotate within about half a minute, the braking torque meets the design requirement.
No. Both brakes must never be opened simultaneously, because the drum would lose braking and dangerous situations could occur.
The high-speed brake USB3-I-560×30-EB800-60 with a set torque of 2570 Nm and the low-speed brake SHI 107, installed in two groups of 1350 Nm each.